Decade counter (falling clock)

using the part in-scene § part parameters

 

Using the part in-scene

Useful facts

  • The decade counter has ten outputs, "0"-"9". Starting with output "0", each output is exclusively set to '1' in turn. After output "9" has been set to '1', the sequence repeats.

 

  • The outputs change when the clock input changes from '1' to '0' as long as the enable ("EN") is set to '1'.

 

  • To reset the counter, set the "R" input to logic 1. Output "0" is then set to '1' regardless of the clock input.

 

 

 

 

Truth table

EN

R

0

1

2

3

4

5

6

7

8

9

0

1

1

0

0

0

0

0

0

0

0

0

1

1

1

0

0

0

0

0

0

0

0

0

0

0

remain unchanged

1

0

count when clock changes from logic 0 to logic 1

 

 

 

 

 

Part Parameters

The part parameters vary according to the logic family selected in the scene's Properties pane (Electronics):

 

 

74HC

4000B

  • (Hidden) supply voltage (VDD)

2-6V

3-15V

  • Output drive current (IO)

4mA

0.4mA

  • Maximum output (low voltage)

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Minimum output (high voltage (VDD=5V))

0.4V (IO=4mA)

0.4V (IO=0.4mA)

  • Maximum voltage (for '0' input)

30% of VDD

30% of VDD

  • Minimum voltage (for '1' input)

70% of VDD

70% of VDD

  • Maximum output current

50mA

50mA

  • Minimum input voltage

-1V

-1V

  • Maximum input voltage

VDD + 1V

VDD + 1V

 